Abstract
Background: Injection of autologous blood can stimulate a healing response in chronic
tendon disorders.
Objective: To comparing the effectiveness of intralesional autologous plasma with
intralesional corticosteroid injection for treatment of plantar fasciitis.
Patients and Methods: Sixty-one adult patients presented to the orthopedic clinic in Erbil
Teaching Hospital from 1st of January, 2015 to 31st of December, 2015, with chronic
proximal plantar fasciitis were included in this study. They were allocated into two groups,
group A, the autologous plasma group (30 patient), and group B, the corticosteroid group
(31 patients). Pain severity was assessed depending on visual analogue scale scores before
treatment and at 2 weeks, 1 month, and 3 months after treatment.
Results: At first week and first month after treatment the pain reduction was significantly
higher among corticosteroid group (P = 0.012 and 0.010, respectively). While at third month
after treatment there was no significant difference in pain reduction (P = 0.11). Reduction in
visual analogue scale scores for both groups was significant over time (p < 0.001). However,
the corticosteroid group showed an earlier sharp drop and a plateau in average pain levels at
the lower end of the scale as early as 2 weeks.
Conclusion: Intralesional autologous plasma injection was effective in lowering pain and
tenderness, although not as quicker than and as effective as the corticosteroid.
tendon disorders.
Objective: To comparing the effectiveness of intralesional autologous plasma with
intralesional corticosteroid injection for treatment of plantar fasciitis.
Patients and Methods: Sixty-one adult patients presented to the orthopedic clinic in Erbil
Teaching Hospital from 1st of January, 2015 to 31st of December, 2015, with chronic
proximal plantar fasciitis were included in this study. They were allocated into two groups,
group A, the autologous plasma group (30 patient), and group B, the corticosteroid group
(31 patients). Pain severity was assessed depending on visual analogue scale scores before
treatment and at 2 weeks, 1 month, and 3 months after treatment.
Results: At first week and first month after treatment the pain reduction was significantly
higher among corticosteroid group (P = 0.012 and 0.010, respectively). While at third month
after treatment there was no significant difference in pain reduction (P = 0.11). Reduction in
visual analogue scale scores for both groups was significant over time (p < 0.001). However,
the corticosteroid group showed an earlier sharp drop and a plateau in average pain levels at
the lower end of the scale as early as 2 weeks.
Conclusion: Intralesional autologous plasma injection was effective in lowering pain and
tenderness, although not as quicker than and as effective as the corticosteroid.
Keywords
Autologous Plasma
Corticosteroids.
Intralesional Injections
Visual Analogue Scale
Keywords
الحقن داخل الآفة، المقياس التناظري البصري، ال