Abstract
The aim of this study was to determine, by a systematic review,
the radiation doses of different dental x-ray devices, their particular
effects, and the cumulative results of various studies done with various
dosimeters. Google scholar was searched from 2014 to 2021 using the
following keywords: radiation dose, dosimeters in dentistry, types of
dosimeters, Cone beam computed tomography (CBCT) radiation. The
references of selected papers were also analyzed. Articles were chosen
that fit the criterion for utilizing dosimeters in dentistry applications.
This review was separated into four sections: (1) biological impacts of
radiation, (2) dosimeter characteristics, (3) dosimeter kinds, and (4)
the findings of numerous investigations employing various dosimeters.
According to a recent assessment of dosimetry based on different
investigations conducted with dosimeters, the effective dosage supplied
has decreased since the introduction of radiography techniques. As
a result, radiological method selection is critical in dental dosage
administration.
the radiation doses of different dental x-ray devices, their particular
effects, and the cumulative results of various studies done with various
dosimeters. Google scholar was searched from 2014 to 2021 using the
following keywords: radiation dose, dosimeters in dentistry, types of
dosimeters, Cone beam computed tomography (CBCT) radiation. The
references of selected papers were also analyzed. Articles were chosen
that fit the criterion for utilizing dosimeters in dentistry applications.
This review was separated into four sections: (1) biological impacts of
radiation, (2) dosimeter characteristics, (3) dosimeter kinds, and (4)
the findings of numerous investigations employing various dosimeters.
According to a recent assessment of dosimetry based on different
investigations conducted with dosimeters, the effective dosage supplied
has decreased since the introduction of radiography techniques. As
a result, radiological method selection is critical in dental dosage
administration.
Keywords
Absorbed dose; panoramic; CBCT; dosimeters
Abstract
الهدف من هذه الدراسة هو تحديد الجرعات الإشعاعية لأجهزة الأشعة السينية المختلفة ، من خلال مراجعة منهجية ، وتأثيراتها الخاصة ، والنتائج التراكمية للدراسات المختلفة التي أجريت باستخدام مقاييس جرعات مختلفة. تم البحث من خلال محرك البحث الباحث الاكاديمي من 2014 إلى 2021 باستخدام الكلمات الدالة الرئيسية التالية: جرعة الإشعاع ، مقاييس الجرعات في طب الأسنان ، أنواع مقاييس الجرعات ، إشعاع التصوير المقطعي المحوسب بالأشعة المخروطية CBCT. تم تحليل مراجع الأوراق البحثية المختارة. تم اختيار المقالات التي تناسب معيار استخدام مقاييس الجرعات في تطبيقات طب الأسنان. تم تقسيم هذه المراجعة إلى أربعة أقسام: (1) التأثيرات البيولوجية للإشعاع ، (2) خصائص مقياس الجرعات ، (3) أنواع مقاييس الجرعات ، (4) نتائج العديد من التحقيقات التي تستخدم مقاييس جرعات مختلفة. وفقًا لتقييم حديث لقياس الجرعات بناءً على تحقيقات مختلفة أجريت باستخدام مقاييس الجرعات ، فإن الجرعة الفعالة المتوفرة قد انخفضت منذ إدخال تقنيات التصوير الشعاعي. نتيجة لذلك ، يعد اختيار الطريقة الإشعاعية أمرًا بالغ الأهمية في إعطاء جرعات الأسنان.
Keywords
الجرعة الممتصة؛ التصوير البانورامي؛ التصوير المقطعي المحوسب بالأشعة المخروطية؛ مقاييس الجرعات