Abstract
This study included the extraction and separation of palladium(II) from its aqueous solutions, by
using swelled polymer crown ether (PDB18C6), and included the following:
After studying the factors that affect the extraction process for palladium ion in order to
find the ideal conditions, it was found that; the palladium ion (II) is extracted when (pH=7), and the
extraction percentage reaches its highest value (E%=91). It was noticed that, the extraction of
palladium ion was impossible from high concentration [0.5M-3.0M] of the acidic medium (HCl ,
H2SO4 , HNO3), but gave extraction percentage (E%=63-64) at the concentration [0.01M] of the
same acid. The percentage extraction of palladium from the alkaline medium (KOH , NaOH) was
very low at [1.0M-3.0M], and it became (E%=51-48) at the concentration [0.01M]. It was found
from experiments that the best shaking time was (60) minutes. It was also found that when adding
ethanol, the best extraction percentage for palladium II was (E%=92), when the volume of ethanol
(20±1Co )in the aqueous phase was (40%V/V) at a temperature
The extraction of palladium from natural medium salts (KCl , NaCl) and medium salt (NH4Cl)
has reached highest (E%-69), (E%=80), at the (1.5M) concentration of both NaCl and KCl,
respectively, and (E%=80) at the (0.01M) concentration of NH4Cl. The selectivity of saturated solid
crown ether polymer towards the extraction of palladium(II) ion, in the present of positive ions
(Li+ ,Na+ ,K+ ,Rb+ ,Ba+2 ,Sr+2 ,Ca +2 ,Cd+2 ,Ni+2 ,Mg+2 ) and presence negative ions
(F− ,Br− ,Cl− ,I− ) , was also studied.
The effect of temperature and thermodynamics functions on the process of extraction of
palladium(II) ions was studied, and it appeared that the extraction enthalpy ΔHex , has a positive
value, which means that the extraction process is endothermic. The free energy for extraction
ΔGex showed a negative value while its entropy ΔSex showed a positive value at all temperature
degrees, which means that the reaction is instantaneous.The separation of copper from palladium ions was carried out on a chromatographic column
filled with the substance (Polydibenzo-18crown-6), which was treated previously with (2.0M) KOH
solution, and using the same solution as a mobile phase to elute Pd (II) first. The process was
performed on eight batches, each batch contained (10ml) from the mobile phase, copper was
recovered from the column, using (1.0M) HCl in five batches, each (10ml) flow-rate was 1ml/min.
using swelled polymer crown ether (PDB18C6), and included the following:
After studying the factors that affect the extraction process for palladium ion in order to
find the ideal conditions, it was found that; the palladium ion (II) is extracted when (pH=7), and the
extraction percentage reaches its highest value (E%=91). It was noticed that, the extraction of
palladium ion was impossible from high concentration [0.5M-3.0M] of the acidic medium (HCl ,
H2SO4 , HNO3), but gave extraction percentage (E%=63-64) at the concentration [0.01M] of the
same acid. The percentage extraction of palladium from the alkaline medium (KOH , NaOH) was
very low at [1.0M-3.0M], and it became (E%=51-48) at the concentration [0.01M]. It was found
from experiments that the best shaking time was (60) minutes. It was also found that when adding
ethanol, the best extraction percentage for palladium II was (E%=92), when the volume of ethanol
(20±1Co )in the aqueous phase was (40%V/V) at a temperature
The extraction of palladium from natural medium salts (KCl , NaCl) and medium salt (NH4Cl)
has reached highest (E%-69), (E%=80), at the (1.5M) concentration of both NaCl and KCl,
respectively, and (E%=80) at the (0.01M) concentration of NH4Cl. The selectivity of saturated solid
crown ether polymer towards the extraction of palladium(II) ion, in the present of positive ions
(Li+ ,Na+ ,K+ ,Rb+ ,Ba+2 ,Sr+2 ,Ca +2 ,Cd+2 ,Ni+2 ,Mg+2 ) and presence negative ions
(F− ,Br− ,Cl− ,I− ) , was also studied.
The effect of temperature and thermodynamics functions on the process of extraction of
palladium(II) ions was studied, and it appeared that the extraction enthalpy ΔHex , has a positive
value, which means that the extraction process is endothermic. The free energy for extraction
ΔGex showed a negative value while its entropy ΔSex showed a positive value at all temperature
degrees, which means that the reaction is instantaneous.The separation of copper from palladium ions was carried out on a chromatographic column
filled with the substance (Polydibenzo-18crown-6), which was treated previously with (2.0M) KOH
solution, and using the same solution as a mobile phase to elute Pd (II) first. The process was
performed on eight batches, each batch contained (10ml) from the mobile phase, copper was
recovered from the column, using (1.0M) HCl in five batches, each (10ml) flow-rate was 1ml/min.